TWCSv3使用说明

2019-05-13

  WINGFIELDSCALE

  WEIGHMODE                                         COUNTMODE


 COMMON BUTTONSONEVERYSCREEN:

-WINGFIELDSCALELOGO–whichwill actas ashort cutkeyto asettings“favoritemenu”orQuickMenu”administrator can selectwhatitems to putinthis“Short

CutkeyundersettingsinQuickMenu.

Wingfield ScaleLogowill be located intopleft ofeveryscreen. Itis passwordprotected. Whenpressed itwillneedto activatedafull keypad.If user accidently

pressesthiskeyhe canpressanywhereoutside the keypadand itwillclosethe keypadand resume normalfunction. ThePasswordis 1937.

-BACK BUTTONTakesuser back to the previousscreen

Located inthelowerrightcornerofeveryscreen

-HOME BUTTONTakesuserto Firstscreen, initialscreen. Actsasareset button.Clearing weights, zeroing scales,sample, counts, etc. Startoverbutton

When UCountModeis on,HomeButtonwill resetthescaleand returnyouto Initial2buttonWEIGHMODE”“COUNT MODE”screen (Slide1)Thatcan change.

When UCountModeis Off,HomeButtonwillresetthe scale.Screenwill appearthesame.GrossWeightwillbe in Large Screen(screen 1)Netwill be in Smallleft

screen (screen 2)andTareWeightwill bein small rightscreen (Screen 3). All zeroedafterHomebuttonis pressed.

HOMEBUTTONis located inthelowerbottomcenterofeveryscreen.

Setting

-SETTINGSBUTTON–

Settingbuttonis located in toprightofeveryscreen. Itispassword protected. Whenpressed itwillneedto activatedafull keypad.If user accidentlypresses thiskey

he can press anywhereoutside thekeypadand itwillclosethekeypadand resume normalfunction.Passwordis 23640.

-CalculatorButton–Availableoneveryscreen. Expandsto fullfunctionCalculator.Buttoncan be enabledand disabledin SETTINGS,

-Wifi Connectivity/SignalStrength

-BluetoothConnectivity/SignalStrength

-BatteryIndicator–Showsstrength,and if itis charging


 UCountMode:ON FirstScreen:

2 Buttons“WEIGHMODE”and“COUNTMODE”

WEIGHMODE

WeighMode-Takesyoutoaweighmodewiththreescreensonelargemainscreen#1,2smaller,#2onlowerleftand#3onlowerright.Gross,Net,Tare.

Therewillbe5Buttonsontheright(andanoptionalPrintbutton)

-TARE–Whichwilldropdowntoanumerickeypadtoenterinthe tare weight.OnceTareweightisenteredtheNetweightmustbereplacedastheweightin the#1large”or

Main”screen.

-MODE–PressingitwillreplaceGrossweightWithNetweightin#1screenandGROSSWEIGHTWILL3screens.Gross,Net,Tare(andAverage,PieceWeight,whenincountmode).

-UNITS–Pressingunitswillflowthemthroughtheavailableunits(kg,lb,oz,troyoz,gr).Theseunitscanbeturnsonandoffin thesettingsmenu.

-ZERO–Typicalzerofunction

-PRINT–TherewillbeanoptionalprintbuttonBelowUnitsthatcanbeturnonorOffbasedonneedinsettings.Thiswillprinttoprinterviaoutputandprotocolthat hasbeen

setupinSettingsmenu

-SAMPLE–GreenButtonwillallowusertocount.SimilarprotocoltoWCS

PressingSamplewillzeroouttopscaleanddisplayonthe#1MainScreenAdd10andpressSAMPLEORaddadifferentquantityandkeyinthatnewquantityandpress

SAMPLE.Thedefault“10”canbechangedinSETTINGS,COUNTING,DEFUALTSAMPLESIZE.

Ifsampleistoolight/small“ERRORwillbedisplayedandthewords“SAMPLEQUANTITYTOOSMALL.REMOVEPARTSFROMSCALE.PRESSSAMPLETOBEGINAGAIN

ANDINCREASEYOURSAMPLESIZE/QUANTITY.

IfSamplesizeisgood

ScalewillSwitchtoScale2anddisplaycountsonthatareonscale2

-Ifscale2isDisabledinSETTINGS,SCALESETUP,SCALE2ENABLE/DISABLE.AfterpressingSAMPLEthesecondtimethescalewillnotswitchtoscale2.

-IfAutobaseSwitchingisturnoffinSETTINGS,COUNTING,AUTOBASESWITCHING.UserwillhavetomanuallyselectScale2.AfterpressingSampleforthe

secondtimethequantitythatisdisplayed(withAutobaseSwitchingOff)countofscale1willbedisplayanduserwillhavetomanuallyselectScale2toget

#1 mainscreentodisplayscale#2dataquantity.

-Administratorcansetthescaleupto taketheinitialSAMPLEonscale2andcountonscale2.ThisisaccomplishedinSETTINGS,COUNTING,SAMPLESCALEASSIGN,

PRE-SAMPLESCALE1or2,AFTERSAMPLESCALE1or2.

-Administratorhastheoptionof enablingAutoZeroScale2inSETTINGS,COUNTING,AUTO-ZEROSCALE2ON/OFF.Whenthisisenabled,(andAutobaseSwitchingis

Enabled)Scale2willbezeroedwhenuserpressesSAMPLEforthesecondtimeandscaleswitchestoScale2todisplaycountsandweightandinstructionsfornext

step.

Userisinstructedto“PlaceContainerofpartsonLargeScale.Entertare weightthenpressTARE.

-Usercanchangetheirtareweightby enteringanothertareweightanditwillNOTaccumulatebut ratheroverwritetheprevioustareweight.Tareweightisclearly

visibleintheTareWeightscreen(#3LowerRightScreen).NetWeightWillbeinthe#2Screen(lowerLeft).PressingModeherewilltoggletheuserthroughdisplayingGross,Net,

Tare,andAPWinthosescreens.

Mode1–Screen1:Quantity,Screen2:NetWeight,Screen3:TareWeight

Mode2–Screen1:Quantity,Screen2:TareWeight,Screen3:AveragePieceWeight(availableineveryunit)

Mode3–Screen1:Gross Weight,Screen2:NetWeight,Screen3:TareWeight

Mode4–Screen1:NetWeight,Screen2:GrossWeight,Screen3:TareWeight


 ScaleSelect:

Scale1andScale2buttonswillchangewhichscaleisdisplayedinthe#1 “main”“large”screen.IfthereisNoscaleconnectedtoscale2 comportorifthereisa

connectionerror(example:cordhasbeencutordamaged)scalewillread“NoConnection”totherightoftheScale2 button.

Totherightofscale1andscale2arelistofpossibleerrorsscale1 orscale2 couldhave

ConnectionError(Shownforeitherscale1 orscale2)

Underload

Overload–anerrorindicationtoomuchweighthasbeenappliedtoloadcellanditisbad

(Weneedalistoferrorsandtheyneedtobeeasilyundersood.)



   SINGLESCALE

MODE


DUALSCALE

MODE


COUNTMODE:

UsercanselectSINGLESCALEMODEorDUALSCALEMODE

- thisscreencanbeonlybe bypassedbyadministratorinsetupbygoingintoSETTINGS,SCALE SETUP,SCALE 2 DISABLE.Thenscalewouldoperateasabenchscale

only.OnlythenwouldtheSINGLESCALEMODE/DUALSCALEMODEbebypassed.Ifuserisoperatingthescale inDUALSCALEMODEuserwillalwayshavetheoptiontouse

SINGLESCALEMODE.Usercanlocktheiranswerandnothavetoanswerthisquestioneverytime.PressingHomebuttonwouldresetlocksandsendbackto1stslide/screen.

SINGLESCALEMODE:

Userwillbeasked“Doyouknowthe tare weightofyourcontainer?”YES”or“NO”(Slide7)

- Usercanlockthisscreenassumingsotheywillnothavetoanswerthisquestionagainandagain.Thescalewillthenafterfinishingcountingskipthisquestionand

proceedtothenext.Hittingthehomebuttonwillresetthe“lock”andhavetheuserbacktothebeginning.Usercanalsousethebackbuttontonavigatetothisscreenandunlock

thisif theyneededto.

“DoyouknowtheTAREweightofyourcontainer?”YES

- WhenuserselectsYESthenscalewillthenpromptusertoADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”thenpress“COUNT(Slide8)

The10defaultsamplesizecanbesetinSETTINGS,COUNTING, DEFAULTSAMPLESIZE

usercanadd10uniformpartsandif theyarelargeenoughusercanpress“COUNT”buttonandproceedtonextscreen

- Ifpartsaresmallanduserneedtochangesamplesizetheycanpress“CHANGESAMPLE”whichwillopenakeypadtoentertheirnewsamplesize.They

canenteranysamplesizetheywant.Thenumbertheyenterwillbethenumberthatcomesupthenexttimetheuserperformsacount(Example:Default

samplesizeis10.Userchangesit to3.thenextcountitwillread3).IftheuserpressesHomeButtonitwillsoftresetthescalebacktothedefaultsample

sizeof10.

- Ifusersamplespartsthatare tooLightweightanerrorscreenwillappearstating“ERRORSAMPLESIZE TOOSMALLREMOVEPARTSFROMSCALETHENPRESS

RESET TOBEGINAGAINANDINCREASEYOURSAMPLEQUANTITY(Slide9)

whenuserpresses“RESET”buttonthescalewillresetand re-zeroand returntoscreenADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”THEN                                                                                                                                                                                                                                                                                                                                   PRESS


COUNT


APW–AveragePieceWeight–buttoncanbepressedatthisscreenallowingtheusertobypassthesamplingprocessandenterindirectlytheAPWofthe particularitem.(Slide18).UserneedtohavetheabilitytochangetounitofmeasurefortheAPWtheyareentering.ItmightbeinLB,KG,OZ,GRAMS,etc. Needtohavetheallavailable.

Pressing“NEXTwillproceedtothefollowingscreen(slide11)

- Userwillbepromptedto“PLACECONTAINEROFPARTSONSMALLSCALEENTERTAREWEIGHTTHENPRESSTARE”

Userwillseethecount“PCS”increase(anddecrease)intheavailablescreenasweightinapplied(andtakenoff)tothescale.

UsercankeyintheirTAREweightwithavailablekeypadandseethenumbersastheykeythemin,theycandeleteanumberiftheyenteredoninwrongandrekeyit.

-PressingtheTARE”buttonproceedyoutotheFinalScreen


FinalScreen(screen12)

Userwillhaveafinalreadingofthecountin#1screen,NetweightinScreen#2,andTareweightinScreen#3.

Userwillbeprompted“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT

UsercanenternewTAREweightandtheTAREweightwillnotadd/sumtothepreviousTAREweight.ITwilloverwrite/replacethepreviousTAREweight.

FullfunctionofTARE,MODE,UNITS,PRINT,ZERO,etc.UsercanselectScale2anduseascale2,applypartsandseeacountthere,immediatelyTARE,etc.

Pressing“NEXTCOUNT”buttonresetscountandproceedsusertothenextcountbyreturningtheusertoSINGLESCALEDUALSCALEscreenoriftheyareusingitas

abench(scale1only)itwouldreturntheuserto“DOYOUKNOWTHETAREWEIGHTOFYOPURCONTAINERYESorNO.Iftheuserhaslockedouttheanswertothat

questionandisusingonlyasscale1 thenit wouldthenproceedhimtotheADD10PARTSTOSMALLSCALEORCHANGESAMPLE”


DO YOUKNOWTHETAREWEIGHTOF

YOURCONTAINER?

   YES                                        NO



 ADD 10PARTSTO SMALLSCALE OR

 THENPRESS


CHANGESAMPLE



  COUNT



APW


ERROR

 SAMPLESIZETOOSMALL

REMOVEPARTSFROMSCALE


THENPRESS


RESET


TO BEGINAGAIN


 ANDINCREASEYOUR SAMPLEQUANTITY



  PLACECONTAINEROFPARTSONLARGESCALE ENTERTAREWEIGHTTHENPRESSTARE

 0PCS


ENTERTAREWEIGHT

0.0



1

2

3

4

5

6

7

8

9

.

0


TARE




  PLACECONTAINEROFPARTSONSMALLSCALE ENTERTAREWEIGHTTHENPRESSTARE

 0PCS


ENTERTAREWEIGHT

0.0



1

2

3

4

5

6

7

8

9

.

0


TARE




 Quantity



RETURNSAMPLETO LARGESCALE ANDRECORDFINALCOUNT.

 TO PROCEED,PRESSNEXT COUNT.

     TARE   

 0000PCS


NEXT

COUNT



NET



0.000LBS

SCALE 1



TARE



 0.000LBS


MODE

1

2

3

4

5

6

7

8

9

.

0


UNITS PRINT*


    ZERO         



 Quantity



RECORDFINALCOUNT.

 TO PROCEED,PRESSNEXT COUNT.

     TARE   

 0000PCS


NEXT

COUNT



NET



0.000LBS

SCALE 1



TARE



 0.000LBS


MODE

1

2

3

4

5

6

7

8

9

.

0


UNITS PRINT*


    ZERO         


 SAMPLE


 WEIGHT

 GROSS

 NET



  0.000LBS TARE


TARE

1

2

3

4

5

6

7

8

9

.

0


MODE


 UNITS


     0.000LBS


  SCALE 1


0.000LBS

APW


PRINT*

     ZERO   


Add 10 & PressSAMPLE

Oradda differentquantity& keyinanewquantitythenpressSAMPLE


SAMPLE



  QUANTITY

 NET

0.000LBS



TARE



0PIECES

0.000LBS


TARE

1

2

3

4

5

6

7

8

9

.

0


MODE UNITS PRINT*


     ZERO         


    SCALE 1


APW


ERRORsampleqtytoosmall,removesamplefromscale.

PressSAMPLEto beginagain&increasesampleqty.


SAMPLE



  QUANTITY

 NET

0.000LBS



TARE



0PIECES

0.000LBS


TARE

1

2

3

4

5

6

7

8

9

.

0


MODE UNITS PRINT*


     ZERO         


  SCALE 1


APW


QUANTITY


Placecontainerof parts on large scale

 Enter tare weightthenpressTARE

  TARE

MODE

1,220PIECES


 UNITS


SAMPLE


NET



0.000LBS


TARE



0.000LBS



1

2

3

4

5

6

7

8

9

.

0


PRINT*


      ZERO         


  SCALE 1


APW



1

2

3

4

5

6

7

8

9

.

0


KEYIN       APW


0.00



UNIT


APW


      PRESS


NEXT


WHENFINISHED


 ADDPARTSTO CONTAINER

0PIECES

 THENPRESS

  NEXT


“DoyouknowtheTAREweightofyourcontainer?”NO

-IfuseranswersNOtoContainerTAREweightquestionthenextscreenwillread“PLACEEMPTYCONTAINERONSCALETHENPRESSSAMPLEPRESSTOSTART”(Slide

22).WhenuserpressesSAMPLEbuttonthescalewilltareoffwhateverisonthescale(theemptycontainer),liketheWCS/WCS2.Thescalethenproceedstothenextscreen

havingtaredoffthecontainer.

-Thenextscreen(slide8).Functionhasbeendescribedbefore.Useraddssampleandpressescountorchangestheirsample.(APW,Error,DefaultSampleSize).

-Thenextscreen(slide19).Useraddspartsto container.Screenonthescreenshowsthatthecountincreasingasuserplacesweightinthecontainer/on

thescale.UserpressesNEXTtoproceedtothefinalscreen(slide12).

-FinalScreenwillbefullfunctionasdescribedearlier.WillstateRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT

-Countisdisplayedin#1Screen.NETweightisScreen#2,andTareweightinScreen#3.Tareweightwillbecalculatedfromwhatwas taredduringthe                                                                                                                                                                                                                                                                                                                                  earlierstep

ofplacingtheemptycontaineronthescaleandpressingSAMPLE.

-UponpressingNEXTCOUNT,userwillbereturnedto3possiblescreens,asdescribedearlierin“DoyouknowtheTAREweightof yourcontainer?”YES

-UseralsohastheoptionofpressingHOMEbuttonwhichwouldsoftresettheuserbacktoWEIGHMODECOUNTMODE.

SINGLESCALE/DUALSCALE

- DUALSCALE

-UserselectsDUALSCALE

- Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7)

- UserselectsYES”

-UserproceedstonextscreenADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8)

-Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button.

- Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize).

-Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale2before

switchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE2ON/OFF.

- ScalehasnowswitchedtoScale2andthedisplayonthescreenisregisteringScale2.

-Userproceedstothenextscreen(Slide10)andisinstructedto“PLACECONTAINEROFPARTSONLARGESCALE.ENTERTAREWEIGHTTHENPRESSTARE”

-Userseesvalue/countincreaseordecreaseinthemainscreenasthecontainerisplacedonScale2(LargeScale).

-Userusesthekeypadonscreentoenterthetare weight.UsercanseethevaluetheyareenteringinthescreenabovekeypadandPressesTAREtoenterthat

weight/valueandproceedtonextscreen.

-NextscreenisthefinalScreen(slide12exceptscale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen#2,TareScreen#3.

-Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT

- Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but

senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2.

-FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4possiblescreens:

- SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen

- DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen.

- ADD10PARTSTOSMALLSCALEORCHANGESAMPLE

- IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st

ScreenWEIGHMODE/COUNTMODE(slide1)


SINGLESCALE/DUALSCALE

- DUALSCALE

- UserselectsDUALSCALE

-Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7)

- Userselects“NO

-UserproceedstonextscreenADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8)

-Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button.

- Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize).

-Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale

2beforeswitchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE 2 ON/OFF.

-ScalehasnowswitchedtoScale2

-ScreenPromptsusertoPLACEEMPTYCONTAINERONSCALETHENPRESSTARE(slide23).

-UserplacestheiremptycontaineronthescaleandpressesZERO.ThiswilltarethecontaineroffScale2andproceedtonextscreen.

-Whateverweight(container)theuserplacesonthescaleandthentaresoffbypressingtheZERObuttonwillbedisplayedinthefinalscreen,screen#3

astheTareweight.

-NextScreen(slide19)promptstheusertoADDPARTSTOCONTAINERTHENPRESSNEXT

- Thisscreenhasascreenthatshowsuseranactivecount(PCS) forwhatisbeingaddedtothescale(orremoved).

-UserpressesNEXTandproceedstothenextscreenwhichisthefinalscreen

-ThefinalScreen(slide12exceptscale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen #2,TareScreen#3.Tareweightwould

becalculatedfromtheprocessofTaring/zeroingtheemptycontainerperformedinslide23.

-Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT

-Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but

senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2.

- FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4 possiblescreens:

- SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen

- DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen.

- ADD10PARTSTOSMALLSCALEORCHANGESAMPLE

- IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st

ScreenWEIGHMODE/COUNTMODE(slide1)



PLACE       EMPTY CONTAINER ON SCALE

 THENPRESS

SAMPLE

PRESS TOSTART



PLACEEMPTYCONTAINERONSCALE

 THENPRESS

TARE



  SCALE SETUP


CALIBRATION


COUNTING



  CONNECTIVITY


UNITS


DISPLAY



TROUBLESHOOTING


QUICKMENU


CHECKWEIGHER



  PRINTER


PresstheSETTINGSGearbuttontoaccesstheSetting/backend/setupmenu:

- Administratorwillbepromptedtoenterinapassword(23640)whichisnotvisibletothepersonenteringitonakeypadthatappearswithanenterbutton.

- UponenteringthepasswordcorrectlytheopeningSETTINGSpage(slide24)willdisplayallbasicoptionsforAdministratortomakeadjustmentsofsetupscale.

- InsideSETTINGS,CALIBRATIONis theonlyheadingthatisPasswordProtected(passwordis54321)

SCALESETUP

- SCALE1 orSCALE2

- SCALE1-      –ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale1ordisableit.Scale1wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaWeighonlyDisplay/Indicator.Thisis rarebutdoeshappen.DefaultwillbeENABLED.Thestatusofthescalewill bevisible

-CAPACITYSCALE1-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defaultvalueis

Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide25)

-RESOLUTIONSCALE1thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe

RESOLUTIONbox

-FILTERINGSCALE1–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3

-ZEROTRACKINGSCALE1–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions

DEFAULTsettingis0 whichisOFFordisabled.

-MOTIONDELAYSCALE1–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand

for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1

second.

-MOTIONDIVISIONSSCALE1– DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0

divisions.DEFAULTis3divisions

-PUSHBUTTONZEROSETTINGSSCALE1keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity.


SCALE2-

–ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale2ordisableit.Scale2wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaSINGLESCALEMODEorbenchscaleonly.DoingthiswouldeliminatetheSINGLESCALEDUALSCALEquestioninthe countingprocessasit wouldbeinSINGLESCALEMODEonly.DEFAULTWILLBEENABLED

-CAPACITYSCALE2-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defasultvalueis

Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide31)

-RESOLUTIONSCALE2thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe

RESOLUTIONbox

-FILTERINGSCALE2–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3.Settingisvisible.

-ZEROTRACKINGSCALE2–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions

DEFAULTsettingis0whichisOFFordisabled.Settingisvisible

-MOTIONDELAYSCALE2–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand

for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1

second.Settingisvisible

- MOTIONDIVISIONSSCALE 2–DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0

divisions.DEFAULTis1divisions.Settingisvisible

-PUSHBUTTONZEROSETTINGSSCALE2keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity.Settingisvisible

UNITS(Slide35)

- DEFAULTCALIBRATIONUNIT

- Administratorisabletoselectdefaultunitsforcalibration.UnitsavailableareLB,KG.Theunitisvisible.

- AVAILABLEUNITS

- Administratorcanselectwhatunitsare availabletotheenduserwhentheenduserpressestheUNITbutton.Availableunitsare:LB,KG,Grams,OZ,

TroyOZ.InonlyLBandKGisselectedthentheuserwillonlybeabletoselectunitsof LBandKG.orifLBistheonlyunitselectedhereLB willbethe

onlyunitthatwillbeselectablebytheUNITbutton.Allunitswillbevisibleandselectable.


CALIBRATION(Slide31)

- SCALE1orSCALE2–Calibrationmenuwillholdthevaluesfromtheprevioustimethescalewascalibrated

- Scalewillalsohavetheabilitytoholdcalibrationscounts”orinordertocalibratewithoutweights.

- Scale2calibrationwillpromptadminforthebasetheyarecalibratingtowithfullalphanumerickeypad.Scalewillbeabletosaveupto10scalesinhistory.Whencalibratingeach

timeitwilldefaulttothepreviousbaseentered(EXAMPLEBC-126).WhenthescaleisturnedonthescalewillprompttheuserwithafullscreenpromptAREYOUCONNECTEDTO

BASEBC-126orthebasetheAdministratorhadenteredinduringcalibration.This featurecanbedisabledinSETTINGS,COUNTING,BASEPROMPTINGON/OFF.WitheachBase

enteredinthescalewillholdinmemorythecountsassociatedwithZEROandtheCALIBRATIONWEIGHT.EachcalibrationafterthefirsttheAdminwillhavetheoptionofselecting

COUNTSCALIBRATIONandperformacalibrationwithoutphysicalweights

SCALE 1

CALBRATIONTYPE

- COUNTSorSPAN

-SPANCALIBRATIONSCALE1

–ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe3typesofZERO:

- NEWZERO–Scaletakesanew zero,withnothingonthescale.

- LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour

calibrationweightandcalibratethescale.

- ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket)

whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan.

-CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration

weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback

upandrunningsometimes.

-Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened.

- AdministratorthenpressesCALIBRATIONbutton.

-aDisplayshowingweightwillappear.AndtheCalibrationwillbegin.

-IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptofAdd

CalibrationWeight

-IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdmintoAddCalibrationWeight.Useraddscal weightandpresses

ENTER.

-ThescalewillthendisplayCALIBRATIONCOMPLETE

IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.

COUNTSCALIBRATIONSCALE1

AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe

aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues.


SCALE2

CALBRATIONTYPE

- COUNTSorSPAN

-SPANCALIBRATIONSCALE2

FirstscreenthatcomesupwillprompttheAdminforthebasethatheiscalibratingto“ISBC-126THEBASEYOUARECALIBRATINGTO?YES/NO

-IfYESthenproceedtoCalibrationpage.IfNOthenAdmincanenterinanewbasewithafullalphanumerickeypad.Total30charactermax

–ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe4typesofZERO:

- NEWZERO–Scaletakesanew zero,withnothingonthescale.

- LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour

calibrationweightandcalibratethescale.

- ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket)

whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan.

- ZEROCOUNTS–Establishingzerobasedoncountsvalue

-CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration

weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback

upandrunningsometimes.

-Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened.

-AdministratorthenpressesCALIBRATIONbutton.

-aDisplayshowingweightwillappear.AndtheCalibrationwillbegin.

-IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptofAdd

CalibrationWeight

-IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdmintoAddCalibrationWeight.Adminaddscalweight,Admincan

seethe1,000LBonthedisplayandpressesENTER.Thescalemaygo to1003LBthenpressEnterscalewilladjustto1000beforestatingCALIBRATIONCOMPLETE

-ThescalewillthendisplayCALIBRATIONCOMPLETE

IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.

COUNTSCALIBRATIONSCALE1

AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe

aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues.


COUNTING



DEFAULTSAMPLESIZE–Admincansetthedefaultsamplesizefrom1to500.Thisiswhatwillshowinslides8&14.Thiswillbechangedbyadropdown

menuwithenteratthebottom,Defaultis10

AUTOBASESWITCHING–AdmincanturnautobaseswitchingON/OFF.ThisisappliedtoCountingwhenin“WEIGHMODE.IfOFF,aftertheinitialsample

istakencountremainsonscaleone,usermustmanuallyselect“SCALE2”toswitchtoSCALE2.IfON,aftertheinitialsampleistakenthecount/weighwill

beswitchtoSCALE2automatically.DEFAULTisON

SAMPLESCALE1/2–Admincansetwhichscaletheywanttoactassamplescale.95%of thetimeuserwouldSAMPLEonscale1,howeverthereare                                                                                                                                                                                                                                                                                                                                                                                      timesthat

requireustosampleonSCALE2becausetheweightofthepartistooheavy.Inthatsituationuserwouldsampleonscale2andcountonscale2.DefaultisON

UCOUNTMODEON/OFF–AdmincanturnUCountModeonandoff.WhenONuserwillflowthroughthescreensof COUNTMODE,SINGLESCALE/DUALSCALE,“DO

YOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”…..

IfOFF,thenuserwillonlybeabletoweighandcountin“WEIGHMODE.

AUTOZEROSCALE2ON/OFF–IfsettoON,Scale2willbeautomaticallyzeroedwhenscaleswitchestoscale2. IfOFF,scalewillneedtobemanually

Zeroedortared

BASEPROMPTINGON/OFF–IfsettoON,whenscaleisturnonitwillpromptuser“ISSCALECONNECTEDTOSCALE                                                                                                                                                                                                                                                                                                                                                                                       ?. IfOFF,itwillnot

prompt.



DISPLAY



SLEEPTIMER–AdmincanturnSLEEPTIMERON/OFF.

- ON- settimedurationforscreentosleep.Admincanselectpresettimes.30sec,1,2,3,4,5,10,15,20,25,30,35,40,45,50,55,60minutes

- OFF–Screenwillstayon

- DEFAULTisONandsetto10 minutes

BRIGHTNESS–Admincansetthebrightnessofthescreen,10-100%by10(10,20,30,etc).DEFAULTis80

CALCULATOR–ON/OFF- Admincanselectwhethertheywantthecalculatoroptionandicontoappear

APW–ON/OFF–AdmincanturnonandofftheAPWbutton.IfOFF,thebuttonwillnotbevisible.IFON,thebuttonwillbevisibleandactive.

PRINT–ON/OFF–AdmincanselecttoturnonoroffthePRINTbutton.

MODE–ON/OFF–AdmincanselecttoturnonorofftheMODEbutton

COLORTHEME–Colorofbackgroundandbuttonscanbesethere.Have5differentpredeterminedsettings

LANGUAGE–BeabletoselectLanguagefortheentirescale.EnglishandSpanisharemostimportant


TROUBLESHOOTING

mV/VOutput–Admincanseerealtimethemillivoltpervoltoutputoftheloadcell.Scale1 andScale2

EXCITATIONVOLTAGE–AdmincanseerealtimeVoltagereadingoffthemainboard.Scale1andScale2.

CURRENTBATTERYCONDITION–Cycles,amps,capacity,chargetimeremaining,voltage,etc

HARDRESET–PasswordProtected(1937)Askareyousure?YES/NO.Thisresetsthescaleto factorydefaultsettings.


QUICKMENU



Admincanselectfromallthemenuwhatitemsfromthemenuhewantsinhereforquickaccess


CONNECTIVITY

WIFI–AdmincanselectWifinetwork,enterpasswords,full rangeofnecessaryrequirements.NeedtoshowNetworkStrengthonmainscreen

Wifisettings.Selectnetwork,forgetnetwork,ShowWifisignalstrength.ScalecanbeaWIFIsource?Willscalehaveitsownwebserver

BLUETOOTH–AdmincanperformsettingsforBluetooth,connecttoprinters,finddevices,sync,etc.Needtoshowbluetoothconnectivityonmainscreen

COMMPORTS- Adminsetsettingsfor:

USBPorts–SettingsforUSBPorts,selectingwhatisinsertedintotheUSBPort.IfitisaJumpDriveScaleshould…….USBportneedstobea dataUSB

port.Minimumof2USBports.Need4.

SERIALPORTS–AdmincanselectSerialPorts.Outputwouldbeaprinter,inputwouldbeascanner

ETHERNETPORTS–Admincansetsettingsfor:

- TCP/IP1

- TCP/IP2

- FTP

MISCROSDPORT–LiketohaveavailableMicroSDport


PRINTER



MODEL/DRIVER–Admincanselectdriverforprintermodeltoprintto.DriversDownloadedintoscalefromfactoryshouldbe Zebra,HP,Starandgeneric(Ticket/Strip printer),.Candownloaddrivervia,Wireless,USB,Ethernet,ifdriverisnotavailable

TICKETEDITOR–AdmincaneditanddesigntickettobeprintedfromPRINTonthe“WEIGHMODE”ScreenorFinalCountScreen.TicketEditorwillprintSelectionof

MODEscreensandtimedatestamp.Barcodes,2Dcodes,WYSIWYG(WhatYouSeeIsWhatYouGet) Editor


CHECKWEIGHER

TARGET–AdmincansetTARGETWeight.Scalewillhowclosetheyare tothe targetwithintherange

RANGE–AdmincansetUNDER(lower)andOVER(upper)weightlimitforcheckweigher.Ifwithintheweightrangeallisnormal.IfweightinlowerthantheUNDER

limitthenentirescreenbackgroundwillturnred.IfOVER,thenentirebackgroundwillturnred.

DIGITALINPUT/OUTPUT–Admincandeterminewhattheywanttoenabletothescaletodowiththatinformation.EXAMPLE:IfOVER,thescalecansendaDIGITAL

OUTPUTsignaltoanactuatorvalvethatwillstopanassemblylinebecausethepartbeingmanufactureredisnotdeterminedweight.

EXAMPLE:TARGETis17Lbs                                           Under15isredscreenanderror.Signalsentout.Over20 error.IdealTargetis17andeachweighmentwillbetrackedtoseehowclose

Underis15Lbs                                                              theyare to17

Overis20Lbs


CAPACITY


SCALE1:30 LBS


SCALE2:1000 LBS


FILTERING


SCALE1:3


SCALE2:3


SCALE1


  ENABLE

 DISABLE

RESOLUTION


SCALE1:0.001LBS


SCALE2:0.1LBS


MOTIONDIVISIONS


SCALE1:3.0


SCALE2:3.0


SCALE2


  ENABLE

ZEROTRACKING


SCALE1:0


SCALE2:0


MOTIONDELAY


SCALE1:1.0S


SCALE2:1.0S


DISABLE


PUSHBUTTONZERO


SCALE1:100.0%


SCALE2:100.0%




  COUNTS

CALIBRATION



SPANCALIBRATION


     SCALE1                                                                                                                         SCALE2


COUNTS


0.000LBS




ZEROTYPE

98758

CAL WEIGHT

109875876

COUNTS



ZEROTYPE

6598651

CAL WEIGHT

659865200

  CALIBRATE                                                                                                                           CALIBRATE


SPANCALIBRATION

   SCALE1                                                                                                                        SCALE2

BASE

BC- 126



ZEROTYPE

NEWZERO



CAL WEIGHT

10LBS


0.000LBS


ZEROTYPE

6598651

CAL WEIGHT

659865200

  CALIBRATE                                                                                                                           CALIBRATE


UNITS

DEFAULT

CALIBRATIONUNITS                                                                                          SELECTUNITS


 oLB

oKG


oLB

oKG

oOZ

oTOZ

oG


COUNTING


DEFAULTSAMPLE

SIZE

   10PCS


AUTOBASESWITCH

ON

OFF


SAMPLESCALE

1

2



   U COUNT

ON

OFF


AUTOZEROSCALE2

ON

OFF


BASE PROMPT

ON

OFF


   CONNECTIVITY


WIFI


COMM PORTS

-USB

-SERIAL


ETHERNETPORTS

-TCIP

-FTP


  BLUETOOTH                                               MICROSD PORTS


EXCITATIONVOLTAGE


SCALE1:0.00


SCALE2:0.00


TROUBLE SHOOTING


mV/VOUTPUT


SCALE1:0.00


SCALE2:0.00


CURRENTBATTERY CONDITION

VOLTS

AMPS

CHARGE

ETC.

HARDRESET



    WINGFDSCALE                                                                                             I-ÞV

    QUICKMENU


  a



BRIGHTNESS


80%



DISPLAY



SLEEPTIMER

10min


CALCULATOR

ON

  OFF



APWBUTTON

ON

 OFF


PRINTBUTTON

ON

OFF


MODEBUTTON ON

OFF


COLORTHEME


BLUE



LANGUAGE


ENGLISH



QRCODE


  ON

OFF


  CHECKWEIGHER

TARGET


0.0LBS



RANGE


UNDER:0.0



OVER:0.0



DIGITALI/O



PRINTER

  MODEL/DRIVER                                                                                                                  TICKETEDITOR


EXIT

SAVECHANGES?

   YES                        NO