WINGFIELDSCALE
WEIGHMODE COUNTMODE
COMMON BUTTONSONEVERYSCREEN:
-WINGFIELDSCALELOGO–whichwill actas ashort cutkeyto asettings“favoritemenu”or “QuickMenu”administrator can selectwhatitems to putinthis“Short
Cut”keyundersettingsinQuickMenu.
Wingfield ScaleLogowill be located intopleft ofeveryscreen. Itis passwordprotected. Whenpressed itwillneedto activatedafull keypad.If user accidently
pressesthiskeyhe canpressanywhereoutside the keypadand itwillclosethe keypadand resume normalfunction. ThePasswordis 1937.
-BACK BUTTON–Takesuser back to the previousscreen
Located inthelowerrightcornerofeveryscreen
-HOME BUTTON–Takesuserto Firstscreen, initialscreen. Actsasareset button.Clearing weights, zeroing scales,sample, counts, etc. Startoverbutton
When UCountModeis on,HomeButtonwill resetthescaleand returnyouto Initial2button“WEIGHMODE”“COUNT MODE”screen (Slide1)Thatcan change.
When UCountModeis Off,HomeButtonwillresetthe scale.Screenwill appearthesame.GrossWeightwillbe in Large Screen(screen 1)Netwill be in Smallleft
screen (screen 2)andTareWeightwill bein small rightscreen (Screen 3). All zeroedafterHomebuttonis pressed.
HOMEBUTTONis located inthelowerbottomcenterofeveryscreen.
Setting
-SETTINGSBUTTON–
Settingbuttonis located in toprightofeveryscreen. Itispassword protected. Whenpressed itwillneedto activatedafull keypad.If user accidentlypresses thiskey
he can press anywhereoutside thekeypadand itwillclosethekeypadand resume normalfunction.Passwordis 23640.
-CalculatorButton–Availableoneveryscreen. Expandsto fullfunctionCalculator.Buttoncan be enabledand disabledin SETTINGS,
-Wifi Connectivity/SignalStrength
-BluetoothConnectivity/SignalStrength
-BatteryIndicator–Showsstrength,and if itis charging
UCountMode:ON FirstScreen:
2 Buttons“WEIGHMODE”and“COUNTMODE”
WEIGHMODE
WeighMode-Takesyoutoaweighmodewiththreescreensonelargemainscreen#1,2smaller,#2onlowerleftand#3onlowerright.Gross,Net,Tare.
Therewillbe5Buttonsontheright(andanoptionalPrintbutton)
-TARE–Whichwilldropdowntoanumerickeypadtoenterinthe tare weight.OnceTareweightisenteredtheNetweightmustbereplacedastheweightin the#1 “large”or
“Main”screen.
-MODE–PressingitwillreplaceGrossweightWithNetweightin#1screenandGROSSWEIGHTWILL3screens.Gross,Net,Tare(andAverage,PieceWeight,whenincountmode).
-UNITS–Pressingunitswillflowthemthroughtheavailableunits(kg,lb,oz,troyoz,gr).Theseunitscanbeturnsonandoffin thesettingsmenu.
-ZERO–Typicalzerofunction
-PRINT–TherewillbeanoptionalprintbuttonBelowUnitsthatcanbeturnonorOffbasedonneedinsettings.Thiswillprinttoprinterviaoutputandprotocolthat hasbeen
setupinSettingsmenu
-SAMPLE–GreenButtonwillallowusertocount.SimilarprotocoltoWCS
PressingSamplewillzeroouttopscaleanddisplayonthe#1MainScreen“Add10andpressSAMPLEORaddadifferentquantityandkeyinthatnewquantityandpress
SAMPLE”.Thedefault“10”canbechangedinSETTINGS,COUNTING,DEFUALTSAMPLESIZE.
Ifsampleistoolight/small“ERROR”willbedisplayedandthewords“SAMPLEQUANTITYTOOSMALL.REMOVEPARTSFROMSCALE.PRESSSAMPLETOBEGINAGAIN
ANDINCREASEYOURSAMPLESIZE/QUANTITY.
IfSamplesizeisgood
ScalewillSwitchtoScale2anddisplaycountsonthatareonscale2
-Ifscale2isDisabledinSETTINGS,SCALESETUP,SCALE2ENABLE/DISABLE.AfterpressingSAMPLEthesecondtimethescalewillnotswitchtoscale2.
-IfAutobaseSwitchingisturnoffinSETTINGS,COUNTING,AUTOBASESWITCHING.UserwillhavetomanuallyselectScale2.AfterpressingSampleforthe
secondtimethequantitythatisdisplayed(withAutobaseSwitchingOff)countofscale1willbedisplayanduserwillhavetomanuallyselectScale2toget
#1 mainscreentodisplayscale#2dataquantity.
-Administratorcansetthescaleupto taketheinitialSAMPLEonscale2andcountonscale2.ThisisaccomplishedinSETTINGS,COUNTING,SAMPLESCALEASSIGN,
PRE-SAMPLESCALE1or2,AFTERSAMPLESCALE1or2.
-Administratorhastheoptionof enablingAutoZeroScale2inSETTINGS,COUNTING,AUTO-ZEROSCALE2ON/OFF.Whenthisisenabled,(andAutobaseSwitchingis
Enabled)Scale2willbezeroedwhenuserpressesSAMPLEforthesecondtimeandscaleswitchestoScale2todisplaycountsandweightandinstructionsfornext
step.
Userisinstructedto“PlaceContainerofpartsonLargeScale.Entertare weightthenpressTARE”.
-Usercanchangetheirtareweightby enteringanothertareweightanditwillNOTaccumulatebut ratheroverwritetheprevioustareweight.Tareweightisclearly
visibleintheTareWeightscreen(#3LowerRightScreen).NetWeightWillbeinthe#2Screen(lowerLeft).PressingModeherewilltoggletheuserthroughdisplayingGross,Net,
Tare,andAPWinthosescreens.
Mode1–Screen1:Quantity,Screen2:NetWeight,Screen3:TareWeight
Mode2–Screen1:Quantity,Screen2:TareWeight,Screen3:AveragePieceWeight(availableineveryunit)
Mode3–Screen1:Gross Weight,Screen2:NetWeight,Screen3:TareWeight
Mode4–Screen1:NetWeight,Screen2:GrossWeight,Screen3:TareWeight
ScaleSelect:
Scale1andScale2buttonswillchangewhichscaleisdisplayedinthe#1 “main”“large”screen.IfthereisNoscaleconnectedtoscale2 comportorifthereisa
connectionerror(example:cordhasbeencutordamaged)scalewillread“NoConnection”totherightoftheScale2 button.
Totherightofscale1andscale2arelistofpossibleerrorsscale1 orscale2 couldhave
ConnectionError(Shownforeitherscale1 orscale2)
Underload
Overload–anerrorindicationtoomuchweighthasbeenappliedtoloadcellanditisbad
(Weneedalistoferrorsandtheyneedtobeeasilyundersood.)
SINGLESCALE
MODE
DUALSCALE
MODE
COUNTMODE:
UsercanselectSINGLESCALEMODEorDUALSCALEMODE
- thisscreencanbeonlybe bypassedbyadministratorinsetupbygoingintoSETTINGS,SCALE SETUP,SCALE 2 DISABLE.Thenscalewouldoperateasabenchscale
only.OnlythenwouldtheSINGLESCALEMODE/DUALSCALEMODEbebypassed.Ifuserisoperatingthescale inDUALSCALEMODEuserwillalwayshavetheoptiontouse
SINGLESCALEMODE.Usercanlocktheiranswerandnothavetoanswerthisquestioneverytime.PressingHomebuttonwouldresetlocksandsendbackto1stslide/screen.
SINGLESCALEMODE:
Userwillbeasked“Doyouknowthe tare weightofyourcontainer?”“YES”or“NO”(Slide7)
- Usercanlockthisscreenassumingsotheywillnothavetoanswerthisquestionagainandagain.Thescalewillthenafterfinishingcountingskipthisquestionand
proceedtothenext.Hittingthehomebuttonwillresetthe“lock”andhavetheuserbacktothebeginning.Usercanalsousethebackbuttontonavigatetothisscreenandunlock
thisif theyneededto.
“DoyouknowtheTAREweightofyourcontainer?”YES
- WhenuserselectsYESthenscalewillthenpromptuserto“ADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”thenpress“COUNT”(Slide8)
The10defaultsamplesizecanbesetinSETTINGS,COUNTING, DEFAULTSAMPLESIZE
usercanadd10uniformpartsandif theyarelargeenoughusercanpress“COUNT”buttonandproceedtonextscreen
- Ifpartsaresmallanduserneedtochangesamplesizetheycanpress“CHANGESAMPLE”whichwillopenakeypadtoentertheirnewsamplesize.They
canenteranysamplesizetheywant.Thenumbertheyenterwillbethenumberthatcomesupthenexttimetheuserperformsacount(Example:Default
samplesizeis10.Userchangesit to3.thenextcountitwillread3).IftheuserpressesHomeButtonitwillsoftresetthescalebacktothedefaultsample
sizeof10.
- Ifusersamplespartsthatare tooLightweightanerrorscreenwillappearstating“ERRORSAMPLESIZE TOOSMALLREMOVEPARTSFROMSCALETHENPRESS
“RESET” TOBEGINAGAINANDINCREASEYOURSAMPLEQUANTITY(Slide9)
whenuserpresses“RESET”buttonthescalewillresetand re-zeroand returntoscreen“ADD 10PARTSTOSMALLSCALEOR“CHANGESAMPLE”THEN PRESS
“COUNT”
APW–AveragePieceWeight–buttoncanbepressedatthisscreenallowingtheusertobypassthesamplingprocessandenterindirectlytheAPWofthe particularitem.(Slide18).UserneedtohavetheabilitytochangetounitofmeasurefortheAPWtheyareentering.ItmightbeinLB,KG,OZ,GRAMS,etc. Needtohavetheallavailable.
Pressing“NEXT”willproceedtothefollowingscreen(slide11)
- Userwillbepromptedto“PLACECONTAINEROFPARTSONSMALLSCALEENTERTAREWEIGHTTHENPRESSTARE”
Userwillseethecount“PCS”increase(anddecrease)intheavailablescreenasweightinapplied(andtakenoff)tothescale.
UsercankeyintheirTAREweightwithavailablekeypadandseethenumbersastheykeythemin,theycandeleteanumberiftheyenteredoninwrongandrekeyit.
-Pressingthe“TARE”buttonproceedyoutotheFinalScreen
FinalScreen(screen12)
Userwillhaveafinalreadingofthecountin#1screen,NetweightinScreen#2,andTareweightinScreen#3.
Userwillbeprompted“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT”
UsercanenternewTAREweightandtheTAREweightwillnotadd/sumtothepreviousTAREweight.ITwilloverwrite/replacethepreviousTAREweight.
FullfunctionofTARE,MODE,UNITS,PRINT,ZERO,etc.UsercanselectScale2anduseascale2,applypartsandseeacountthere,immediatelyTARE,etc.
Pressing“NEXTCOUNT”buttonresetscountandproceedsusertothenextcountbyreturningtheusertoSINGLESCALEDUALSCALEscreenoriftheyareusingitas
abench(scale1only)itwouldreturntheuserto“DOYOUKNOWTHETAREWEIGHTOFYOPURCONTAINER”YESorNO.Iftheuserhaslockedouttheanswertothat
questionandisusingonlyasscale1 thenit wouldthenproceedhimtothe“ADD10PARTSTOSMALLSCALEORCHANGESAMPLE”
DO YOUKNOWTHETAREWEIGHTOF
YOURCONTAINER?
YES NO
ADD 10PARTSTO SMALLSCALE OR
THENPRESS
CHANGESAMPLE
COUNT
APW
ERROR
SAMPLESIZETOOSMALL
REMOVEPARTSFROMSCALE
THENPRESS
RESET
TO BEGINAGAIN
ANDINCREASEYOUR SAMPLEQUANTITY
PLACECONTAINEROFPARTSONLARGESCALE ENTERTAREWEIGHTTHENPRESSTARE
0PCS
ENTERTAREWEIGHT
0.0
|
|
PLACECONTAINEROFPARTSONSMALLSCALE ENTERTAREWEIGHTTHENPRESSTARE
0PCS
ENTERTAREWEIGHT
0.0
|
|
Quantity
RETURNSAMPLETO LARGESCALE ANDRECORDFINALCOUNT.
TO PROCEED,PRESSNEXT COUNT.
TARE
0000PCS
NEXT
COUNT
|
NET
0.000LBS
SCALE 1
TARE
0.000LBS
MODE
|
ZERO
Quantity
RECORDFINALCOUNT.
TO PROCEED,PRESSNEXT COUNT.
TARE
0000PCS
NEXT
COUNT
|
NET
0.000LBS
SCALE 1
TARE
0.000LBS
MODE
|
ZERO
SAMPLE
WEIGHT
GROSS
NET
0.000LBS TARE
TARE
|
UNITS
|
SCALE 1
0.000LBS
APW
PRINT*
ZERO
Add 10 & PressSAMPLE
Oradda differentquantity& keyinanewquantitythenpressSAMPLE
SAMPLE
QUANTITY
NET
0.000LBS
TARE
0PIECES
0.000LBS
TARE
|
ZERO
SCALE 1
APW
ERRORsampleqtytoosmall,removesamplefromscale.
PressSAMPLEto beginagain&increasesampleqty.
SAMPLE
QUANTITY
NET
0.000LBS
TARE
0PIECES
0.000LBS
TARE
|
ZERO
SCALE 1
APW
QUANTITY
Placecontainerof parts on large scale
Enter tare weightthenpressTARE
TARE
|
UNITS
SAMPLE
NET
0.000LBS
TARE
0.000LBS
|
ZERO
SCALE 1
APW
|
0.00
UNIT
APW
PRESS
NEXT
WHENFINISHED
ADDPARTSTO CONTAINER
0PIECES
THENPRESS
NEXT
“DoyouknowtheTAREweightofyourcontainer?”NO
-IfuseranswersNOtoContainerTAREweightquestionthenextscreenwillread“PLACEEMPTYCONTAINERONSCALETHENPRESSSAMPLEPRESSTOSTART”(Slide
22).WhenuserpressesSAMPLEbuttonthescalewilltareoffwhateverisonthescale(theemptycontainer),liketheWCS/WCS2.Thescalethenproceedstothenextscreen
havingtaredoffthecontainer.
-Thenextscreen(slide8).Functionhasbeendescribedbefore.Useraddssampleandpressescountorchangestheirsample.(APW,Error,DefaultSampleSize).
-Thenextscreen(slide19).Useraddspartsto container.Screenonthescreenshowsthatthecountincreasingasuserplacesweightinthecontainer/on
thescale.UserpressesNEXTtoproceedtothefinalscreen(slide12).
-FinalScreenwillbefullfunctionasdescribedearlier.Willstate“RECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT”
-Countisdisplayedin#1Screen.NETweightisScreen#2,andTareweightinScreen#3.Tareweightwillbecalculatedfromwhatwas taredduringthe earlierstep
ofplacingtheemptycontaineronthescaleandpressingSAMPLE.
-UponpressingNEXTCOUNT,userwillbereturnedto3possiblescreens,asdescribedearlierin“DoyouknowtheTAREweightof yourcontainer?”YES
-UseralsohastheoptionofpressingHOMEbuttonwhichwouldsoftresettheuserbacktoWEIGHMODECOUNTMODE.
SINGLESCALE/DUALSCALE
- DUALSCALE
-UserselectsDUALSCALE
- Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7)
- Userselects“YES”
-Userproceedstonextscreen“ADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8)
-Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button.
- Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize).
-Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale2before
switchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE2ON/OFF.
- ScalehasnowswitchedtoScale2andthedisplayonthescreenisregisteringScale2.
-Userproceedstothenextscreen(Slide10)andisinstructedto“PLACECONTAINEROFPARTSONLARGESCALE.ENTERTAREWEIGHTTHENPRESSTARE”
-Userseesvalue/countincreaseordecreaseinthemainscreenasthecontainerisplacedonScale2(LargeScale).
-Userusesthekeypadonscreentoenterthetare weight.UsercanseethevaluetheyareenteringinthescreenabovekeypadandPressesTAREtoenterthat
weight/valueandproceedtonextscreen.
-NextscreenisthefinalScreen(slide12except“scale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen#2,TareScreen#3.
-Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT”
- Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but
senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2.
-FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4possiblescreens:
- SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen
- DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen.
- ADD10PARTSTOSMALLSCALEORCHANGESAMPLE
- IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st
ScreenWEIGHMODE/COUNTMODE(slide1)
SINGLESCALE/DUALSCALE
- DUALSCALE
- UserselectsDUALSCALE
-Userwillbepromptedwith“DOYOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”YESorNO(Slide7)
- Userselects“NO”
-Userproceedstonextscreen“ADD 10PARTSTOSMALLSCALEORCHANGESAMPLETHENPRESSCOUNT”(Slide8)
-Usercanaddthedefault10orchangethatnumberbypressingthe“CHANGESAMPLE”button.
- Detailsofthecompletefunctionofthisslideareexplainedalreadyasitisthesame.(APW,SamplesizeError,DefaultSampleSize).
-Useraddtherequestedsamplequantitytothescaleandpresses“COUNT”button.WhenuserpressesCOUNTbuttonscalewillautomaticallyTAREScale
2beforeswitchingtonextscreen.ThiscanbeturnedON/OFFFinSETTINGS,COUNTING,AUTOZEROSCALE 2 ON/OFF.
-ScalehasnowswitchedtoScale2
-ScreenPromptsusertoPLACEEMPTYCONTAINERONSCALETHENPRESSTARE(slide23).
-UserplacestheiremptycontaineronthescaleandpressesZERO.ThiswilltarethecontaineroffScale2andproceedtonextscreen.
-Whateverweight(container)theuserplacesonthescaleandthentaresoffbypressingtheZERObuttonwillbedisplayedinthefinalscreen,screen#3
astheTareweight.
-NextScreen(slide19)promptstheuserto“ADDPARTSTOCONTAINERTHENPRESSNEXT”
- Thisscreenhasascreenthatshowsuseranactivecount(PCS) forwhatisbeingaddedtothescale(orremoved).
-UserpressesNEXTandproceedstothenextscreenwhichisthefinalscreen
-ThefinalScreen(slide12except“scale2”wouldbeselected).Scalewoulddisplayfinalcountinmaindisplay#1,NetinScreen #2,TareScreen#3.Tareweightwould
becalculatedfromtheprocessofTaring/zeroingtheemptycontainerperformedinslide23.
-Userwouldbepromptedto“RETURNSAMPLETOLARGESCALEANDRECORDFINALCOUNT.TOPROCEEDPRESSNEXTCOUNT”
-Thisscreenfunctionsthesameasothersscreensfinalscreens.ThemaindifferenceisthisscreendefaultstoScale2,displayingscale2.Usercanselectscale1,but
senseuserhasselectedDUALSCALEMODE,thescaleassumestheuserwantsto countonScale2.
- FromheretheuserpressesNEXTCOUNTwhichtakestheuserto4 possiblescreens:
- SINGLESCALE/DUALSCALEscreen(slide5),unlesslocked.Iflockedwillproceedtonextscreen
- DOYOUKNOWTHETAREWEIGHTYOURCONTAINER?YES/NO(slide7).Ifthisscreenislockedthenproceedtonextscreen.
- ADD10PARTSTOSMALLSCALEORCHANGESAMPLE
- IfuserpressestheHOMEbuttonthescalewillsoftreset(lockbuttonsresetandsamplesizesresettodefaultandscalere-zero-ed)and returnto1st
ScreenWEIGHMODE/COUNTMODE(slide1)
|
PLACE EMPTY CONTAINER ON SCALE
THENPRESS
SAMPLE
PRESS TOSTART
|
PLACEEMPTYCONTAINERONSCALE
THENPRESS
TARE
SCALE SETUP
CALIBRATION
COUNTING
CONNECTIVITY
UNITS
DISPLAY
TROUBLESHOOTING
QUICKMENU
CHECKWEIGHER
|
PRINTER
PresstheSETTINGSGearbuttontoaccesstheSetting/backend/setupmenu:
- Administratorwillbepromptedtoenterinapassword(23640)whichisnotvisibletothepersonenteringitonakeypadthatappearswithanenterbutton.
- UponenteringthepasswordcorrectlytheopeningSETTINGSpage(slide24)willdisplayallbasicoptionsforAdministratortomakeadjustmentsofsetupscale.
- InsideSETTINGS,CALIBRATIONis theonlyheadingthatisPasswordProtected(passwordis54321)
SCALESETUP
- SCALE1 orSCALE2
- SCALE1- –ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale1ordisableit.Scale1wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaWeighonlyDisplay/Indicator.Thisis rarebutdoeshappen.DefaultwillbeENABLED.Thestatusofthescalewill bevisible
-CAPACITYSCALE1-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defaultvalueis
Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide25)
-RESOLUTIONSCALE1–thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe
RESOLUTIONbox
-FILTERINGSCALE1–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3
-ZEROTRACKINGSCALE1–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions
DEFAULTsettingis0 whichisOFFordisabled.
-MOTIONDELAYSCALE1–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand
for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1
second.
-MOTIONDIVISIONSSCALE1– DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0
divisions.DEFAULTis3divisions
-PUSHBUTTONZEROSETTINGSSCALE1–keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity.
SCALE2-
–ENABLE/DISABLE–Thisneedstobeaselectabletogglethatisavailabletotouchandenablescale2ordisableit.Scale2wouldbedisabledinasituation wheretheuserwantstousetheTWCSasaSINGLESCALEMODEorbenchscaleonly.DoingthiswouldeliminatetheSINGLESCALEDUALSCALEquestioninthe countingprocessasit wouldbeinSINGLESCALEMODEonly.DEFAULTWILLBEENABLED
-CAPACITYSCALE2-thisopensupandkeypadtowheretheAdmincanenterinthefullscalecapacityoftheScale.DEFAULTis30LB,60LB,100LB.Defasultvalueis
Visible.ThechangevaluewillbevisibleinCAPACITYSCALE1box(Slide31)
-RESOLUTIONSCALE2–thisopensakeypadwhereAdmincanenterintheRESOLUTION.DEFAULTisdeterminedbyPRIS.The resolutionwillbevisibleinthe
RESOLUTIONbox
-FILTERINGSCALE2–Pleasedeterminearangefrom1-10.Highvibration= 10.Low/novibration=0.Defaultsetting3.Settingisvisible.
-ZEROTRACKINGSCALE2–Enable/Disable.Alwaysoff/disabledincountingfeatureorwhenscaleiscounting/sampling.Ifon,setupbydivisions.Range0-4divisions
DEFAULTsettingis0whichisOFFordisabled.Settingisvisible
-MOTIONDELAYSCALE2–TIMEsettingbeforescalesendssignalortakesareading,examplepressingPRINTbuttonandscalewaitsuntilitisstableat3divisionsand
for1secondandthenitwillprint.AnotherExampleistheCOUNT/SAMPLING.Timeisenteredincanbe0.0- 10.0seconds0isnodelay).DEFAULTissetto1
second.Settingisvisible
- MOTIONDIVISIONSSCALE 2–DIVISIONS.Setthedivisionsthescaleneedstoseeatstablebeforeproceedingtonextsteporsendingsignal.Valuesare0.0-20.0
divisions.DEFAULTis1divisions.Settingisvisible
-PUSHBUTTONZEROSETTINGSSCALE2–keyinthepercentageofwhatyoucanzerooffthescale.Needtobeableto zero100% ofcapacity.Settingisvisible
UNITS(Slide35)
- DEFAULTCALIBRATIONUNIT
- Administratorisabletoselectdefaultunitsforcalibration.UnitsavailableareLB,KG.Theunitisvisible.
- AVAILABLEUNITS
- Administratorcanselectwhatunitsare availabletotheenduserwhentheenduserpressestheUNITbutton.Availableunitsare:LB,KG,Grams,OZ,
TroyOZ.InonlyLBandKGisselectedthentheuserwillonlybeabletoselectunitsof LBandKG.orifLBistheonlyunitselectedhereLB willbethe
onlyunitthatwillbeselectablebytheUNITbutton.Allunitswillbevisibleandselectable.
CALIBRATION(Slide31)
- SCALE1orSCALE2–Calibrationmenuwillholdthevaluesfromtheprevioustimethescalewascalibrated
- Scalewillalsohavetheabilitytoholdcalibrations“counts”orinordertocalibratewithoutweights.
- Scale2calibrationwillpromptadminforthebasetheyarecalibratingtowithfullalphanumerickeypad.Scalewillbeabletosaveupto10scalesinhistory.Whencalibratingeach
timeitwilldefaulttothepreviousbaseentered(EXAMPLEBC-126).Whenthescaleisturnedonthescalewillprompttheuserwithafullscreenprompt“AREYOUCONNECTEDTO
BASEBC-126orthebasetheAdministratorhadenteredinduringcalibration.This featurecanbedisabledinSETTINGS,COUNTING,BASEPROMPTINGON/OFF.WitheachBase
enteredinthescalewillholdinmemorythecountsassociatedwithZEROandtheCALIBRATIONWEIGHT.EachcalibrationafterthefirsttheAdminwillhavetheoptionofselecting
COUNTSCALIBRATIONandperformacalibrationwithoutphysicalweights
SCALE 1
CALBRATIONTYPE
- COUNTSorSPAN
-SPANCALIBRATIONSCALE1
–ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe3typesofZERO:
- NEWZERO–Scaletakesanew zero,withnothingonthescale.
- LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour
calibrationweightandcalibratethescale.
- ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket)
whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan.
-CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration
weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback
upandrunningsometimes.
-Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened.
- AdministratorthenpressesCALIBRATIONbutton.
-aDisplayshowingweightwillappear.AndtheCalibrationwillbegin.
-IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptof“Add
CalibrationWeight”
-IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdminto“AddCalibrationWeight”.Useraddscal weightandpresses
ENTER.
-ThescalewillthendisplayCALIBRATIONCOMPLETE
IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.
COUNTSCALIBRATIONSCALE1
AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe
aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues.
SCALE2
CALBRATIONTYPE
- COUNTSorSPAN
-SPANCALIBRATIONSCALE2
FirstscreenthatcomesupwillprompttheAdminforthebasethatheiscalibratingto“ISBC-126THEBASEYOUARECALIBRATINGTO?YES/NO
-IfYESthenproceedtoCalibrationpage.IfNOthenAdmincanenterinanewbasewithafullalphanumerickeypad.Total30charactermax
–ZEROTYPEAdministratorcanselectthetypeofzerothatthescalewilltake.Inadropdownmenutherewillbe4typesofZERO:
- NEWZERO–Scaletakesanew zero,withnothingonthescale.
- LASTZERO–Scalereferencesthepreviouszeroandisabletorezeroitselfevenifthereisaloadonthescale(thenyoucanaddyour
calibrationweightandcalibratethescale.
- ONLYZERO–Reestablishingzero.Examplewehavecalibratedascalewithandcustomerremovesweightoffthescale(standorbracket)
whichchangesthe zerolongterm.Weneedto calibratezeroagainandkeepthespan.
- ZEROCOUNTS–Establishingzerobasedoncountsvalue
-CALIBRATIONWEIGHT–AdministratorpressadropdownmenuwhichwillopenakeypadwithENTERbuttonwhereAdministratorcankeyinCalibration
weight.Notlimitedtospecificweightsorpercentageofcapacity.Example:Cancalibrate5,000LBscalewith100LBnotrecommendedbutneededtogetscalesback
upandrunningsometimes.
-Theweightthatisenteredherewillbesavedandbedefaultedasthevaluenexttimeitisopened.
-AdministratorthenpressesCALIBRATIONbutton.
-aDisplayshowingweightwillappear.AndtheCalibrationwillbegin.
-IfNEWZEROisselected,Adminwillbepromptedtounloadscale,thenpressENTER.(scalewillshow0.000oractualweight),andproceedstopromptof“Add
CalibrationWeight”
-IfLASTZEROisselectedscalewilluselastzerodespitecurrentloadandmoveontoPromptingAdminto“AddCalibrationWeight”.Adminaddscalweight,Admincan
seethe1,000LBonthedisplayandpressesENTER.Thescalemaygo to1003LBthenpressEnterscalewilladjustto1000beforestatingCALIBRATIONCOMPLETE
-ThescalewillthendisplayCALIBRATIONCOMPLETE
IfAdminselectsONLYZEROscalewillonlyperformzeroandthatisit.
COUNTSCALIBRATIONSCALE1
AdmincanselectCOUNTCALIBRATIONandhewillproceedtothenextscreenwhichwillshowhimZEROandcountsvalueforthelastcalibrationperformedthenthe
aCountsvaluefortheweightthatisnormallyapplied.AlltheAdimisrequiredtodoispressCALIBRATIONbuttonandthescalewillloadinthosevalues.
COUNTING
DEFAULTSAMPLESIZE–Admincansetthedefaultsamplesizefrom1to500.Thisiswhatwillshowinslides8&14.Thiswillbechangedbyadropdown
menuwithenteratthebottom,Defaultis10
AUTOBASESWITCHING–AdmincanturnautobaseswitchingON/OFF.ThisisappliedtoCountingwhenin“WEIGHMODE”.IfOFF,aftertheinitialsample
istakencountremainsonscaleone,usermustmanuallyselect“SCALE2”toswitchtoSCALE2.IfON,aftertheinitialsampleistakenthecount/weighwill
beswitchtoSCALE2automatically.DEFAULTisON
SAMPLESCALE1/2–Admincansetwhichscaletheywanttoactassamplescale.95%of thetimeuserwouldSAMPLEonscale1,howeverthereare timesthat
requireustosampleonSCALE2becausetheweightofthepartistooheavy.Inthatsituationuserwouldsampleonscale2andcountonscale2.DefaultisON
UCOUNTMODEON/OFF–AdmincanturnUCountModeonandoff.WhenONuserwillflowthroughthescreensof COUNTMODE,SINGLESCALE/DUALSCALE,“DO
YOUKNOWTHETAREWEIGHTOFYOURCONTAINER?”…..
IfOFF,thenuserwillonlybeabletoweighandcountin“WEIGHMODE”.
AUTOZEROSCALE2ON/OFF–IfsettoON,Scale2willbeautomaticallyzeroedwhenscaleswitchestoscale2. IfOFF,scalewillneedtobemanually
Zeroedortared
BASEPROMPTINGON/OFF–IfsettoON,whenscaleisturnonitwillpromptuser“ISSCALECONNECTEDTOSCALE ?”. IfOFF,itwillnot
prompt.
DISPLAY
SLEEPTIMER–AdmincanturnSLEEPTIMERON/OFF.
- ON- settimedurationforscreento“sleep”.Admincanselectpresettimes.30sec,1,2,3,4,5,10,15,20,25,30,35,40,45,50,55,60minutes
- OFF–Screenwillstayon
- DEFAULTisONandsetto10 minutes
BRIGHTNESS–Admincansetthebrightnessofthescreen,10-100%by10(10,20,30,etc).DEFAULTis80
CALCULATOR–ON/OFF- Admincanselectwhethertheywantthecalculatoroptionandicontoappear
APW–ON/OFF–AdmincanturnonandofftheAPWbutton.IfOFF,thebuttonwillnotbevisible.IFON,thebuttonwillbevisibleandactive.
PRINT–ON/OFF–AdmincanselecttoturnonoroffthePRINTbutton.
MODE–ON/OFF–AdmincanselecttoturnonorofftheMODEbutton
COLORTHEME–Colorofbackgroundandbuttonscanbesethere.Have5differentpredeterminedsettings
LANGUAGE–BeabletoselectLanguagefortheentirescale.EnglishandSpanisharemostimportant
TROUBLESHOOTING
mV/VOutput–Admincanseerealtimethemillivoltpervoltoutputoftheloadcell.Scale1 andScale2
EXCITATIONVOLTAGE–AdmincanseerealtimeVoltagereadingoffthemainboard.Scale1andScale2.
CURRENTBATTERYCONDITION–Cycles,amps,capacity,chargetimeremaining,voltage,etc
HARDRESET–PasswordProtected(1937)Askareyousure?YES/NO.Thisresetsthescaleto factorydefaultsettings.
QUICKMENU
Admincanselectfromallthemenuwhatitemsfromthemenuhewantsinhereforquickaccess
CONNECTIVITY
WIFI–AdmincanselectWifinetwork,enterpasswords,full rangeofnecessaryrequirements.NeedtoshowNetworkStrengthonmainscreen
Wifisettings.Selectnetwork,forgetnetwork,ShowWifisignalstrength.ScalecanbeaWIFIsource?Willscalehaveitsownwebserver
BLUETOOTH–AdmincanperformsettingsforBluetooth,connecttoprinters,finddevices,sync,etc.Needtoshowbluetoothconnectivityonmainscreen
COMMPORTS- Adminsetsettingsfor:
USBPorts–SettingsforUSBPorts,selectingwhatisinsertedintotheUSBPort.IfitisaJumpDriveScaleshould…….USBportneedstobea dataUSB
port.Minimumof2USBports.Need4.
SERIALPORTS–AdmincanselectSerialPorts.Outputwouldbeaprinter,inputwouldbeascanner
ETHERNETPORTS–Admincansetsettingsfor:
- TCP/IP1
- TCP/IP2
- FTP
MISCROSDPORT–LiketohaveavailableMicroSDport
PRINTER
MODEL/DRIVER–Admincanselectdriverforprintermodeltoprintto.DriversDownloadedintoscalefromfactoryshouldbe Zebra,HP,Starandgeneric(Ticket/Strip printer),.Candownloaddrivervia,Wireless,USB,Ethernet,ifdriverisnotavailable
TICKETEDITOR–AdmincaneditanddesigntickettobeprintedfromPRINTonthe“WEIGHMODE”ScreenorFinalCountScreen.TicketEditorwillprintSelectionof
MODEscreensandtimedatestamp.Barcodes,2Dcodes,WYSIWYG(WhatYouSeeIsWhatYouGet) Editor
CHECKWEIGHER
TARGET–AdmincansetTARGETWeight.Scalewillhowclosetheyare tothe targetwithintherange
RANGE–AdmincansetUNDER(lower)andOVER(upper)weightlimitforcheckweigher.Ifwithintheweightrangeallisnormal.IfweightinlowerthantheUNDER
limitthenentirescreenbackgroundwillturnred.IfOVER,thenentirebackgroundwillturnred.
DIGITALINPUT/OUTPUT–Admincandeterminewhattheywanttoenabletothescaletodowiththatinformation.EXAMPLE:IfOVER,thescalecansendaDIGITAL
OUTPUTsignaltoanactuatorvalvethatwillstopanassemblylinebecausethepartbeingmanufactureredisnotdeterminedweight.
EXAMPLE:TARGETis17Lbs Under15isredscreenanderror.Signalsentout.Over20 error.IdealTargetis17andeachweighmentwillbetrackedtoseehowclose
Underis15Lbs theyare to17
Overis20Lbs
|
|
ENABLE
DISABLE
|
|
ENABLE
|
|
PUSHBUTTONZERO | |
SCALE1:100.0% | |
SCALE2:100.0% |
COUNTS
CALIBRATION
SPANCALIBRATION
SCALE1 SCALE2
COUNTS
0.000LBS
|
ZEROTYPE | 6598651 |
CAL WEIGHT | 659865200 |
CALIBRATE CALIBRATE
SPANCALIBRATION
SCALE1 SCALE2
|
|
ZEROTYPE | 6598651 |
CAL WEIGHT | 659865200 |
CALIBRATE CALIBRATE
UNITS
DEFAULT
CALIBRATIONUNITS SELECTUNITS
oLB
oKG
oLB
oKG
oOZ
oTOZ
oG
COUNTING
DEFAULTSAMPLE
SIZE
10PCS
AUTOBASESWITCH
ON
OFF
SAMPLESCALE
1
2
U COUNT
ON
OFF
AUTOZEROSCALE2
ON
OFF
BASE PROMPT
ON
OFF
CONNECTIVITY
WIFI
COMM PORTS
-USB
-SERIAL
ETHERNETPORTS
-TCIP
-FTP
BLUETOOTH MICROSD PORTS
|
mV/VOUTPUT | |
SCALE1:0.00 | |
SCALE2:0.00 |
|
WINGFDSCALE I-ÞV
QUICKMENU
|
|
SLEEPTIMER
10min
CALCULATOR
ON
OFF
APWBUTTON
ON
OFF
PRINTBUTTON
ON
OFF
MODEBUTTON ON
OFF
|
|
ON
OFF
CHECKWEIGHER
|
|
PRINTER
MODEL/DRIVER TICKETEDITOR
EXIT
SAVECHANGES?
YES NO